Function: | Steam Boilers |
---|---|
Fuel: | Waste Heat |
Installation: | Assembled Boiler |
Structure: | Water Tube |
Media: | Waste Heat |
Water Circulation: | Natural Circulation |
Customization: |
---|
Suppliers with verified business licenses
Boiler type: | Q48/900-18-5.3/485 Vertical type & Module structure |
|
Drawing No. | FR1802 | |
Inlet flue gas flow | 48,000. | Nm3/h |
Inlet Flue gas temperature | 900 | ºC |
Rated boiler evaporation | 18 | t/h |
Rated Steam pressure | 5.3 | MPa |
rated Steam temperature | 485 | ºC |
Feedwater temperature | 104 | ºC |
Cold air temperature | 20 | ºC |
Exhaust gas temperature | 167 | ºC |
Boiler design efficiency | 80.2 | % |
HEATING SURFACE AREA | ||
Superheater heating surface area | 118 | m2 |
Water cooling system heating surface area | 792.4 | m2 |
Economizer heating surface area | 855.8 | m2 |
HYDRAULIC TEST | ||
Hydraulic test | 7.0 | Mpa |