10t-80t Waste Gas Combustion Boiler

Certification: ISO9001, GB
Application: Industrial
Voltage: 380V
Packing:Exported Standard/According to R: Standard:GB, SGS, Ce, ASME
Production Capacity:600PCS/Year: Origin:China
Transport Package: Exported Standard/According to Requirement
Customization:
Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
SZS10-1.25-Q
Specification
A level
Trademark
huayuan
Origin
Origin: China
HS Code
8402190000
Production Capacity
600 PCS/Per Year

Product Description

  1. SCOPE OF APPLICATION & BOILER CHARACTERISTICS
1.1 According to the user's process and steam consumption requirements, this low calorific value waste gas high-efficiency burner system is composed of incinerator, waste heat boiler, high temperature air preheater, economizer, waste gas heater, and low temperature air preheater.
1.2.  Product model: SZS10-1.25-Q
1.3  Product features: This product has a compact structure, micro-negative pressure operation, good sealing performance, no environmental pollution, low system resistance (<2000Pa), high utilization rate, convenient operation, safe and reliable, the boiler is shipped from the factory, reducing the boiler's The manufacturing cost is convenient, the construction is short, the installation period is short, the cost is low, and the capital construction investment is low.
3. Scope of application: the high-temperature flue gas produced by the high-efficiency exhaust gas combustion boiler generates steam through the waste heat boiler as an auxiliary energy source for its heat supply, gas supply, power supply and power, improve the overall utilization rate of heat energy, reduce the fuel consumption index and reduce electricity Consumption to obtain economic benefits.


 
 
 
 
BOILER DESIGN SPECIFICATION
 
Boiler type
 
SZS10-1.25-Q
Rated output       t/h
 
10
Rated steam pressure    Mpa
 
1.25
Rated steam temperature    ºC
 
193
Feed water temperature    ºC
 
105
Cold air temperatre     ºC
 
20
Hot air temperature    ºC
 
~ 278
Exhaust gas inlet temperature 20
Exhaust gas outlet temperature ~ 124
Heating area
 
 Waste heat boiler  m2
 
337.6
Economizer      m2 796.1
High temperature air preheater      m2
 
1252
Exhaust gas heater  m2
 
309.8
Low temperature air preheater         m2
 
103.5
   
   
Boiler design efficiency  % 90.3
Boiler design exhaust temperature     ºC
 
~100
Water volume of water cooling system          m3
 
12
Hydrostatic test     Mpa
 
1.65
Applicable fuel
 
 Low calorific value waste gas 
 
Calculating the net heating value of fuel     KJ/nm³ 1786





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 14001
Export Year
2008-05-01