BOILER DESIGN SPECIFICATION |
||
Boiler type |
DHS20-1.6-Q | |
Rated output t/h |
20 | |
Rated steam pressure Mpa |
1.6 | |
Rated steam temperature ºC |
204 | |
Feed water temperature ºC |
104 | |
Cold air temperatre ºC |
20 | |
Hot air temperatre ºC | 350 | |
Heating area |
heating surface area of water cooling system m2 |
572 |
heating surface area of high temperature Air preheater m2 |
518 | |
heating surface area of medium temperature Air preheater | 563 | |
heating surface area of low temperature Air preheater | 598 | |
heating surface area of Economizer m2 |
316 | |
Boiler design exhaust temperature ºC |
200 | |
Water volume of boiler m3 |
24 | |
Overall hydraulic test pressure Mpa |
2.0 | |
Applicable fuel |
Mixed fuel : waste water + waste liquid + waste gas + biogas |
|
Designed efficiency % | 76 | |