MAIN PARAMETERS OF THE WASTE HEAT RECOVERY BOILER AS FOLLOWS
Boiler type: |
Q110/900-35-3.82/450 |
Drawing No. |
FR351 |
Flue gas flow |
110,000. |
Nm3/h |
Inlet Flue gas temperature |
900 |
ºC |
Rated boiler evaporation |
35 |
t/h |
Stem pressure |
3.82 |
MPa |
Superheated Steam temperature |
~450 |
ºC |
Feedwater temperature |
90(deaeration soft water) |
ºC |
|
HEATING SURFACE AREA |
Superheater heating surface area |
185 |
m2 |
Boiler proper heating surface area |
1710 |
m2 |
Economizer heating surface area |
830 |
m2 |
Air preheater heating surface area |
945 |
m2 |
|
HYDRAULIC TEST |
Superheater |
5.15 |
Mpa |
Boiler proper |
5.15 |
Mpa |
economizer |
5.53 |
Mpa |
FEATURES OF THE WASTE HEAT RECOVERY BOILER FOR CHEMICAL INDUSTRY
1.The steam shall be produced by the waste heat of production process, resulting in energy saving and increasing benefit.
2.The waste heat recovery boiler shall feature the following advantages:Compact structure, no pollution, small system resistance, easy operation, and full waste heat recovery.
3.The design of the waste heat recovery boiler shall be in accordance with user's process parameter.